<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-22 16-39-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 40 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 24 kHz 5411 0,0370
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,71 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 24 kHz MIN: 14 kHz % above 76 kHz: 0,0370 Acquired: 2026/01/22 16.38.16 Total samples: 5411 Equivalent time: 0:04:30 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 5,8 dBr MIN: 2,3 dBr AVE: 4,71 dBr % above 12,2 dBr: 0,0 Last value: 4,0 dBr (2026/01/22 16.38.16) 16.24 16.26 16.28 16.30 16.32 16.34 16.36 16.38 0 2 4 6 Pm [dBr]